Byte
Field
Description
3
Write data (LSB)
4
Read_Value_Select
Selects the function for reading
data.
5
Write_Value_Select
Selects the function for writing
data.
6
free
free
free
free
free
free
free
free
7
free
free
Res
Power
Res
Test
Set
Test
Res
Tare
Set Ta-
re
Set
Zero
In direct access, control bits are
independent of the write or read
request. "Free" bits are applica-
tion specific.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Field
Size
Function
Write data
4 bytes
Data to be written as a binary 32-bit value with plus or
minus sign.
Data type: DINT
Read_Value_Select
1 byte
Function for selecting the read request
Write_Value_Select
1 byte
Function for selecting the write request
ResPower
1 bit
PowerFail
is reset.
ResTest
1 bit
The
test
operating mode is finished.
SetTest
1 bit
The
test
operating mode is started.
Now the test value can be read out by reading the
gross weight.
ResTare
1 bit
Tare is reset.
SetTare
1 bit
The weighing point is tared.
SetZero
1 bit
The weighing point is set to zero.
Read window (MISO)
Byte
Field
Description
0
Read data (MSB)
1
Read data
2
Read data
3
Read data (LSB)
Contains the data to be written,
e.g. gross value.
4
Read_Value_Selected
Read_Value_Select
(function)
from the write window is mirro-
red if the data in "Read data" is
available.
Transmitter Series PR 5211
7 ProfiBus interface
Minebea Intec
EN-62
Summary of Contents for PR 5211 Series