19
Installation
Set the motor hall sensor header according to the hall effect
feedback spacing. Jumper SW502 if the hall effect feedback
spacing is 120°. Do not add a jumper if the hall effect feedback
spacing is 60°. The factory default is 120º (installed).
Jumper Settings
Input Voltage Range Select (SW501)
Jumper SW501 selects the DC input voltage range. Jumper
terminals 1 and 2 for a voltage range of 15 - 40 VDC (this is the
factory setting). Jumper terminals 2 and 3 for 12 - 15 VDC input.
Hall Sensor Spacing (SW502)
Figure 8. Jumper Locations
HALL
SENSOR
SPACING
SW502
INPUT
VOLTAGE
SELECT
SW501
NOTE:
This drive provides a +5 VDC, 20mA maximum
output to drive the Hall sensors. To run with encoder (hall-
track) feedback, refer to Figure 7. This voltage is provided at
TB501 terminal 11 (Vref) and terminal 12 (ground).
250-0288.qxd 6/9/00 1:05 PM Page 19
Summary of Contents for MMBOSS Series
Page 1: ...Model MMBOSS05 24DC 1Q MMBOSS Series User s Manual...
Page 7: ...Tables Table 1 Line Fuse Chart 8 Table 2 Replacement Parts 41 v...
Page 8: ......
Page 10: ......
Page 11: ...3 Dimensions Figure 1 MMBOSS Series Dimensions...
Page 12: ......
Page 21: ...13 Installation Figure 4 PCB Power Fuse and Motor Connections TO MOTOR DIR COM COM...
Page 28: ......
Page 34: ...Figure 9 Decelerate to Minimum Speed Switch 26 Operation...
Page 52: ...Notes...
Page 53: ...Notes...
Page 54: ...Notes...