14
Installation
Warning
Do not reverse power input leads or apply reverse voltage at
the drive terminals. The drive will be damaged.
Connect switches to COM terminal 1 only. Do not connect
switches to COM terminal 12. Terminal 12 is to be used for
external hall sensors and encoders only.
Optional switch connections
Connect the following switches to the terminal plug as shown in
Figure 5.
ENABLE/DISABLE switch
Install a single-pole, single- throw switch between the ENABLE
and COM terminals (Figure 5). Close the switch to disable the
drive and coast the motor to a stop. Leave open to enable the
drive and run the motor.
RUN/BRAKE switch
Install a single-pole, single- throw switch between the BRAKE
and COM terminals (Figure 5). Close the switch to brake the
motor to a stop. Open the switch to run the motor and accelerate
to set speed.