8
Installation
Heat sinking
The MMBOSS series drive contains sufficient heat sinking in its
basic configuration. There is no need for additional heat sinking.
Fusing
All Minarik drives should be protected by fuses. Use fast acting
fuses, such as Bussman® 3AG or equivalent, rated for
approximately 150% – 200% of the maximum phase current.
Fuse only the BUS+ DC input voltage line. See the fuse chart
below for recommended line fuse sizes:
Table 1. Line Fuse Chart
Maximum Phase
Fuse Rating
Current (DC Amps)
( Amps)1
0.5
1
0.8
1.5
1.5
3
2.6
5
3.5
8
5.0
10
Notes:
1. Use 250 volt fuses regardless of the input voltage.