- 3.13 -
8.
Remove the ink at the wiper and the bracket
using a swab dampened with cleaning
fluid(SPC-0137).
•
If the wiper wears out, replace the wiper with a
new one. Complete this function before replac-
ing the wiper. (
page 5.5)
9.
Holding the projections at both ends, insert the
wiper which has cleaned into place.
10. Press the [ENTER] key.
11. Fill the cap with the cleaning fluid(SPC-0137)
using a dropper.
12. Close the front cover.
13. Press the [ENTER] key.
14. Press the [ ] and [ ] key to select the time to
leave. (1-99 min)
Normally set 1 min.
Fill the Liquid.
COMPLETED
:ent
STATION
LEAVING
: 2 min