- 2.17 -
STEP
1.
The device enters the LOCAL mode.
Push the [REMOTE] key and put the device back into the
LOCAL mode.
2.
Push the [TEST] key.
3.
Push the [ENTER] key.
The device plots the test pattern.
4.
Check the test patterns.
If a failure occurs, proceed with step 5; otherwise, terminate
the operation.
5.
Push the [CLEANING] key.
6.
Push the jog key [ ][ ][ ][ ] to select the
head for cleaning.
Select the head number by the set, 12 or 34.
7.
Select the method of cleaning by pushing the
JOG keys [ ] and [ ].
soft
:
Select this if there is any missing line.
normal
:
Select this if any line is bent.
strong
:
Select this if inferior plotting cannot be
recovered after [normal] or [soft] cleaning.
8.
Push the [ENTER] key.
Cleaning starts. The operation status is displayed as * in the
second line.
9.
The device revert the LOCAL mode.
10. Repeat steps 2, and check the result of the test
plotting.
Repeat steps 2 to 8 until normal plotting result is obtained.
< LOCAL >
width : 1272 mm
TEST DRAW
< ENT >
∗
∗
TEST DRAW
∗
∗
< LOCAL >
width : 1272 mm
TEST
CLEANING
CLEANING
TYPE
: normal
CLEANING
TYPE
: soft
CLEANING
TYPE
: strong
CLEANING
ACTIVE
* * * * * - - - - - - - - - - -
CLEANING
HEAD SET
:
1
2 . 3 4
< LOCAL >
width : 1272 mm
CLEANING
HEAD SET
:
-
- . 3 4
CLEANING
HEAD SET
: - - .
3
4
Summary of Contents for JV22-130
Page 2: ......
Page 34: ... 1 18 ...
Page 86: ... 4 14 ...
Page 120: ... A 6 ...
Page 125: ......
Page 126: ...PrintedinJapan D201031 MIMAKI ENGINEERING Co Ltd 2006 ...