Overview
Cutting end point is too long or too short.
Remedy1
Adjust the END CORR. value in the cutting conditions. (
Remedy2
Adjust Pattern A for Adjust Eccentricity in Adjust Cutter in tool
adjustments. (
Overview
The tial cutter is displaced to the right of the direction of
movement.
Remedy
Adjust Pattern B for Adjust Eccentricity in Adjust Cutter in tool
adjustments. (
Overview
The cut is rotated clockwise or counterclockwise, and the cutting
start point is too far forward or backward.
Remedy
See the remedies described for Sample B and Sample C.
Overview
The cut is rotated clockwise or counterclockwise, and the tial
cutter is displaced to the right or left.
Remedy
See the remedies described for Sample B and Sample E.