background image

6

7

Emissivity (E)

Set the emissivity of the surface 
being scanned (0.95 is the 
default). During a temperature 
scan, the set emissivity value 
is displayed. Refer to an Emis-
sivity Table for proper surface 
settings.

Laser ON/OFF (

)

Turns the laser pointer on and 
off while the IR continues to take 
readings. 

°F / °C (F)

Determine if temperature read-
ings are displayed in Fahrenheit 
or Celsius.

Alarm ON, OFF, MUTE

Use the Alarm ON/OFF button 
to turn the alarm on and off, and 
mute the alarm after it sounds. 
The bell icon will go off. The 
temperature reading will con-
tinue to 

fl

 ash as long as it is 

outside the preset range.

Fuel Gauge

The battery icon displays the remaining battery 
life. Charge the battery according to the battery 
and charger manual.   

ACCESSORIES

For a complete listing of accessories refer to your

 

MILWAUKEE 

Electric Tool catalog or go online to 

www.milwaukeetool.com. To obtain a catalog, con-
tact your local distributor or a service center listed 
on the back cover of this operator’s manual.

WARNING 

Always remove battery 

pack before changing or removing acces-
sories. Only use accessories specifically 
recommended for this tool. Others may be 
hazardous. 

FIVE YEAR TOOL  

LIMITED WARRANTY

MAINTENANCE

WARNING 

To reduce the risk of per-

sonal injury and damage, never immerse your 
tool, battery pack or charger in liquid or allow 
a liquid to fl ow inside them.

WARNING 

To reduce the risk of injury, 

always remove the batteries from the tool 
before performing any maintenance. Never 
disassemble the tool. Contact a MILWAUKEE
 
service facility for ALL repairs.

Maintaining Tool 

Keep your tool in good repair by adopting a regular 
maintenance program. After six months to one year, 
depending on use, return the tool to 

a MILWAUKEE

 

service facility for:
If the tool does not start or operate at full power 
with fully charged batteries, clean the contacts 
on the battery door. If the tool still does not work 
properly, return the tool to a 

MILWAUKEE

 service 

facility for repairs.

Cleaning the Laser Windows

Clean the laser windows with a soft, moist cloth to 
keep them clean and clear. Remove battery pack 
before cleaning.

Cleaning

Clean dust and debris from tool vents. Keep tool 
handles clean, dry and free of oil or grease. Use 
only mild soap and a damp cloth to clean the tool 
since certain cleaning agents and solvents are 
harmful to plastics and other insulated parts. Some 
of these include gasoline, turpentine, lacquer thin-
ner, paint thinner, chlorinated cleaning solvents, 
ammonia and household detergents containing 
ammonia. Never use 

fl

 ammable or combustible 

solvents around tools.

Repairs

For repairs, return the tool to the nearest service 
center listed on the back cover of this operator's 
manual.

Selecting SETTINGS

Press the SET button to display one of the fol-
lowing. Then use the arrow buttons to determine 
the value:

Alarm High (HI)

If the set temperature is reached 
during a scan, “HI”,  

 

, and 

temperature will 

fl

 ash. 

Alarm Low (LOW)

If the set temperature is reached 
during a scan, “LOW",  

 ,

 and 

temperature will 

fl

 ash.

Log (LOG)

Use the arrow keys to select 
the data location (1-20). Pull the 
trigger to scan the temperature. 
Press the LOG key to save the 
reading to the selected data 
location.

MILWAUKEE

 Test & Measurement Products (includ-

ing bare tool, li-ion battery pack(s) and battery char-
ger but excluding alkaline batteries) are warranted 
to the original purchaser only to be free from defects 
in material and workmanship.  Subject to certain 
exceptions, 

MILWAUKEE

 will repair or replace any 

part on this product which, after examination, is deter-
mined by 

MILWAUKEE 

to be defective in material or 

workmanship for a period of 

fi

 ve (5) years* after the 

date of purchase.  Return the Test & Measurement 
tool and a copy of proof of purchase to the nearest 
Milwaukee Electric Tool Corporation - factory Service 
Center.  This warranty does not apply to damage that 

MILWAUKEE 

determines to be from repairs made or 

attempted by anyone other than 

MILWAUKEE

 autho-

rized personnel, misuse, alterations, abuse, normal 
wear and tear, lack of maintenance, or accidents.
*The warranty period for the LITHIUM-ION battery 
pack that ships with the Test & Measurement tool is 
two (2) years from the date of purchase.  *Alkaline 
battery that ships with Test & Measurement tool is 
separately warranted by the battery manufacturer. 
*The warranty period for a NON-CONTACT VOLT-
AGE DETECTOR – 2201 20 is one (1) year from 
the date of purchase.
Warranty Registration is not necessary to obtain 
the applicable warranty on 

MILWAUKEE

 product. 

The manufacturing date of the product will be used 
to determine the warranty period if no proof of 
purchase is provided at the time warranty service 
is requested.
ACCEPTANCE OF THE EXCLUSIVE REPAIR 
AND REPLACEMENT REMEDIES DESCRIBED 
HEREIN IS A CONDITION OF THE CONTRACT 
FOR THE PURCHASE OF EVERY 

MILWAUKEE

 

PRODUCT.  IF YOU DO NOT AGREE TO THIS 
CONDITION, YOU SHOULD NOT PURCHASE THE 
PRODUCT.  IN NO EVENT SHALL 

MILWAUKEE

 

BE LIABLE FOR ANY INCIDENTAL, SPECIAL, 
CONSEQUENTIAL OR PUNITIVE DAMAGES, OR 
FOR ANY COSTS, ATTORNEY FEES, EXPENSES, 
LOSSES OR DELAYS ALLEGED TO BE AS A CON-
SEQUENCE OF ANY DAMAGE TO, FAILURE OF, 
OR DEFECT IN ANY PRODUCT INCLUDING, BUT 
NOT LIMITED TO, ANY CLAIMS FOR LOSS OF 
PROFITS.  THIS WARRANTY IS EXCLUSIVE AND 
IN LIEU OF ALL OTHER WARRANTIES OR CON-
DITIONS, WRITTEN OR ORAL, EXPRESSED OR 
IMPLIED.  WITHOUT LIMITING THE GENERALITY 
OF THE FOREGOING, 

MILWAUKEE

 DISCLAIMS 

ANY IMPLIED WARRANTY OF MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR USE OR 
PURPOSE, AND ALL OTHER WARRANTIES.
This warranty applies to product sold in the U.S.A., 
Canada and Mexico only.

Summary of Contents for 2276-20

Page 1: ...tros l ser Temp Gun de 12 V Cat No No de Cat 2276 20 2277 20 TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE...

Page 2: ...an make a connection from one terminal to another Shorting the battery termi nals together may cause burns or a fire 1 Display 2 K Type thermocouple input 3 Key pad 4 Lock on button 5 Nameplate 6 Lase...

Page 3: ...you continue to hold the trigger the icon is displayed along with the sur face temperature primary measurement along with any selected mode readings secondary measurement 3 Release the trigger HOLD i...

Page 4: ...ver of this operator s manual Selecting SETTINGS Press the SET button to display one of the fol lowing Then use the arrow buttons to determine the value Alarm High HI If the set temperature is reached...

Page 5: ...le produit dans un endroit frais et sec Ne pas l entreposer dans des endroits o la temp rature peut d passer 50 C 120 F par exemple un endroit expos directement la lumi re du soleil un v hicule ou un...

Page 6: ...a batterie de l outil Pour ins rer la batterie dans l outil la glisser sur le corps de l outil S assurer qu elle se loge ferme ment en place AVERTISSEMENT Il faut toujours re tirer la batterie avant d...

Page 7: ...du laser l aide d un linge doux et humide afin de s assurer qu elles de meurent propres et claires Retirer la batterie avant de proc der au nettoyage Nettoyage Nettoyer les vents de l outil des d bris...

Page 8: ...elo a una instalaci n de servicio MILWAUKEE Almacene el producto en un lugar limpio y seco No lo guarde en lugares donde la tem peratura supere los 50 C 120 F como por ejemplo bajo la luz solar direct...

Page 9: ...0 10 el objetivo tiene un di metro de 76 3 A una distancia de 204 cm 80 el objetivo tiene un di metro de 50 mm 2 A una distancia de 100 cm 40 el objetivo tiene un di metro de 25 mm 1 Selecci n de MODO...

Page 10: ...TOR DE VOLTAJE SIN CONTACTO 2201 20 es de un 1 a o a partir de la fecha de compra No se necesita registro de garant a para obtener la garant a correspondiente de los productos MILWAUKEE Se usar la fec...

Page 11: ...7 00 AM 6 30 PM Central Time or visit our website at www milwaukeetool com Additionally we have a nationwide network of authorized Distributors ready to assist you with your tool and accessory needs C...

Reviews: