Programming
138
Peak load
When "Peak load" is selected, the programme is allocated a peak
load function.
If the input peak load signal is present and the programme is in a
heating phase, the heating is switched off and the programme is
stopped. "Programme stopped by peak load function" appears in
the display.
If the programme is in Thermostop, the safety interval of the
Thermostop is maintained.
Hot water control
Create
Programme header
:
:
Yes
Peak load
No
Select the "Peak load" programme function.
You have the following options:
– Yes
– No
Hot water control
When "Hot water control" is selected, you have the choice between
automatic water valve guide and control of pre-selected water valves.
Price
Create
Programme header
:
:
No
No
Hot water control
You have the following options:
– No
– Yes
If "Yes" is selected for Hot water control, the water intake valves are
"automatically" activated in such a way that the required
temperature for the wash cycle is already reached from the first
intake of water by alternately activating cold or hot water valves.
If automatic valve control is not selected, the pre-selected water
valves are activated in conjunction with Hot water control "Yes"
without regard to the required temperature.
Summary of Contents for PW 811