Programme chart
100
Mask programmes
Masks
are programmes for washing and disinfecting breathing masks with head straps.
Put the head bands over the masks to protect the visors before loading the machine.
Put each mask into its own protective bag and fasten it.
Remove the masks from the bags after processing.
Spin damp, empty bags using the
Spin wash bags
programme.
Masks
60 °C
Fill ratio/Load
size
Load
Face masks with head straps
PW 811 -
10 masks
PW 814 -
13 masks
PW 818 -
15 masks
Programme
sequence
Disinfection* 60 °C, 20 min.
4 rinses
Masks with pre-wash
60 °C
Load
For heavily soiled masks with head straps
Programme
sequence
Pre-cleaning 30 °C
Disinfection* 60 °C, 20 min.
4 rinses
Spin wash bags
Load
Face mask bags
1:20
Programme
sequence
Spin
* The disinfection parameters for chemo-thermal disinfection (temperature, temperature holding time, and dosages) must
be set on site to suit cleaning agents and disinfectants.
To avoid recontamination, the water for the rinse cycles in the disinfection programmes is
not supplied via the detergent dispenser.
Do not wash masks with connections for helmet-mask combinations.
The clasps are likely to scratch visors.
Use a suitable detergent. Observe the manufacturer's instructions.