Washing without dispensing drawer
30
Dispenser calibration
Dispenser pump 1
0/1
0
t:
P: No
100 ml
V:
s
Press multifunction button 0/1.
Stop the pump by pressing button 0/1, or the pump will stop
automatically after 60 seconds.
Measure the required amount into the measuring vessel.
Dispenser calibration
Dispenser pump 1
0/1
30 s
t:
P: 200 ml/min
V:
100 ml
Enter the amount measured in field "V:".
The throughput P is calculated in ml/min by the controls.
Press the
"Save" button.
The measured value is assigned to the pump.
Reattach the hose.