Programming
159
Dispensing
throughput
(D1 to D13)
The throughput of the connected dispenser pumps can be set from
0 ml/min to 9999 ml/min in 1 ml/min steps.
Access the following content:
Supervisor level
Settings
Dispensing correction factor
Dispensing throughput
Select "Dispensing throughput".
The following will appear in the display:
Settings
ml
Dispenser pump 2
Dispenser pump 1
Dispensing throughput
: 6000,0
min
/
No
:
Options:
– No
– 1 to 9999.0 ml/min
Dispensing
correction factor
(D1 to D13)
The correction factor can be used if an adjustment is made to the
liquid dispensing. If, for example, the dispensing agent for dispenser
pump D1 were altered (to a higher concentration), a quick adjustment
can be made with the correction factor.
Calculate the correction factor using the following formula:
Correction factor D1 =
new quantity dispenser pump D1
current quantity dispenser pump D1
Access the following content:
Supervisor level
Settings
Dispenser level reminder
Dispensing correction factor
Select "Dispensing correction factor".
Settings
Dispenser pump 2
Dispenser pump 1
Dispensing correction factor
: 1,00
1,00
:
You have the following options:
– 2
– 1.99 to 0.01
Once you exit the supervisor level, the new dispensing amounts are
used in the programmes but the programming is not changed.