Technical Information
CVA4070 / CVA4075 Coffee Systems
6.2
Service Mode Overview
Initial requirements
1. Switch the appliance off.
Accessing
Note
Complete the access within 10 seconds.
1. Touch pad
Clear
and hold.
2. Touch pad
On/Off
once.
3. Release pad
Clear.
4. Touch pad
Clear
3 times and at the 3rd time, hold it until the service
mode appears.
Acknowledgement indicator
The display shows the positions of the
Service
mode.
Options
1. Touch the pad next to the desired position (refer).
2. Touch the pad next to the desired activation (refer).
3.
Back:
Touch pad
Clear.
Save and quit
1. Touch pad On/Off.
Position
Display / Activation
Description / Results
EPX
e. g. ID01087 V21
The ID number of the control
electronic is displayed
ID NUMBER
EPL
e. g. ID33849 V10
The ID number of the power
electronic is displayed
registered faults,
refer to 021 Table 2
All faults that have occurred so
far are indicated. To show the
fault description, touch the pad
next to the fault.
FAULT MEMORY
Delete
All saved faults are deleted.
Open
The solenoid for steam is
opened.
COMPONENT
TEST
STEAM
VALVE
Close
The solenoid for steam is
closed.
Table 6-8:
CVA4070 Service Mode (Continued on Table 6-9)