Chapter 9 Initial Start-Up
The following work should be completed in the office before you go to the future location of the device:
1. If necessary, create a customer on the myDatanet server (see "myDatanet Server Manual " 805002).
2. Within the desired customer, create a new site/application based on the IoT application
"myDatalogGauge" for operation of the myDatalogGauge 3G on the myDatanet server (see "Creating
the site" on page 131).
3. Configure the created site/application according to your requirements (see "Site configuration" on page
79).
The following settings should be adjusted:
1. Activate the required measurement channels by selecting the mode and specifying the serial
number of the BLE Gauge (see "Measurement channels" on page 83).
Note:
If you have purchased the myDatalogGauge 3G as a set (data logger including up to 2 BLE
Gauge sensor modules), the serial numbers of the BLE Gauge are already saved in the memory
of the data logger. In this case, it suffices to select "Automatic" mode. The saved serial number
is displayed in the input field for the serial number, although it cannot be changed.
2. If already known, enter the intended installation height of the pressure sensor in the input field for
the "Sensor Offset" parameter (see "Measurement channels" on page 83).
3. Ensure that the "Trimming" parameter is set to 0 (see "Measurement channels" on page 83).
4. Use the DeviceConfig configuration program to establish a Bluetooth connection (Bluetooth Low
Energy) between the myDatalogGauge 3G and your PC (see "Establishing a connection to a device
with Bluetooth Low Energy interface" on page 108).
5. Activate the synchronisation between myDatalogGauge 3G , DeviceConfig and the myDatanet
server. To do so, initially select the "Sync with server" checkbox and then click on the button illustrated
below. The checkbox and button are both located on the "Sync" tab of the DeviceConfig configuration
program (see ""Sync" tab" on page 112).
Note:
The "Sync with server" checkbox is only displayed if your PC is already connected to the
Internet.
The following tasks are to be completed on site, directly at the deployment site of the device:
6. Place the pressure sensor and the BLE Gauge in the final installation position (see "Suspended
installation of the BLE Gauge " on page 52).
7. If you have not already done so in the office, enter the installation height of the pressure sensor in the
input field for the "Sensor Offset" parameter (see "Measurement channels" on page 83).
8. Insert the activation module in the sensor recess of the myDatalogGauge 3G (see "Inserting the
activation module" on page 61).
9. Use the DeviceConfig configuration program to establish a Bluetooth connection (Bluetooth Low
Energy) between the myDatalogGauge 3G and your PC (see "Establishing a connection to a device
with Bluetooth Low Energy interface" on page 108).
Rev. 01
69
Summary of Contents for myDatalogGauge 3G
Page 2: ......
Page 10: ...2 2 BLE Gauge 10 Rev 01 ...
Page 11: ...Chapter 2 Declaration of conformity Rev 01 11 ...
Page 12: ......
Page 13: ...Chapter 3 Ex certification Chapter 3 Ex certification 3 1 BLE 3G Gateway ATEX Rev 01 13 ...
Page 14: ...14 Rev 01 ...
Page 15: ...Chapter 3 Ex certification Rev 01 15 ...
Page 16: ...16 Rev 01 ...
Page 17: ...Chapter 3 Ex certification 3 2 BLE Gauge Rev 01 17 ...
Page 18: ...18 Rev 01 ...
Page 19: ...Chapter 3 Ex certification Rev 01 19 ...
Page 20: ...20 Rev 01 ...
Page 134: ......
Page 140: ......
Page 152: ......
Page 154: ......