![Microscan Quadrus MINI Imager User Manual Download Page 375](http://html1.mh-extra.com/html/microscan/quadrus-mini-imager/quadrus-mini-imager_user-manual_1788315375.webp)
Quadrus MINI Imager User’s Manual
A-13
Appendices
Serial Command Format
Serial commands are of two types: utility and configuration.
Rules that apply to both utility and configuration commands
• A less than
<
and greater than
>
character enclose the commands.
• Commands and data are “case sensitive.” That is, characters must be entered as upper
or lower case, as specified.
Serial Utility Commands
These are sent during operations and are not followed by
<A>
or
<Z>
.
Serial Configuration “K” Commands
These begin with a single “K”
character followed by a 3-digit numeric character, data
fields, and an initializing command, as follows:
<
K
numeric parameter,data,data,...etc.
><
initializing command
>
An initializing command
<A>
or
<Z>
may follow the command. A
<Z>
initializes the
imager’s memory and saves for power-on; an
<A>
initializes the imager’s memory but
does not save for power-on.
For example, to enable
UPC
and save the change for power-on, send
<K473,1><Z>
.
To change
Baud Rate
and reset without saving changes for power-on, send
<K100,3><A>
.
Serial Configuration Command Conventions
• All data fields (except the last) must be followed by a comma (
without a space
).
• NUL cannot be used. The characters
<
,
>
, and
,
can be used, but only if entered as hex
pairs (see
ASCII Character Entry Modifier
on page 3-32).
• All fields preceding a modified field must be included.
• If there is no change in preceding fields, then commas alone can be entered in these
fields. For example, if only the last field in the following command is changing,
<K100,4,1,0,0>
can be entered as
<K100,,,,0>
.
• All fields
following
a modified field can be omitted. For example, to change
Baud Rate
only, send
<K100,3>
.
Summary of Contents for Quadrus MINI Imager
Page 1: ...Quadrus MINI Imager User s Manual P N 84 006300 Rev...
Page 12: ...xii Quadrus MINI Imager User s Manual Statement of RoHS Compliance...
Page 98: ...4 20 Quadrus MINI Imager User s Manual Additional Notes about Calibration...
Page 128: ...5 30 Quadrus MINI Imager User s Manual Setting Up the Imager for EZ Trax...
Page 180: ...6 52 Quadrus MINI Imager User s Manual Background Color...
Page 238: ...7 58 Quadrus MINI Imager User s Manual Configuring EZ Trax Output...
Page 298: ...10 32 Quadrus MINI Imager User s Manual Skew Correction...
Page 318: ...11 20 Quadrus MINI Imager User s Manual Request All Configuration Database Settings...
Page 348: ...13 24 Quadrus MINI Imager User s Manual Other Operational Serial Commands...
Page 362: ...14 14 Quadrus MINI Imager User s Manual Ordered Output Filter...