![Microscan Quadrus MINI Imager User Manual Download Page 190](http://html1.mh-extra.com/html/microscan/quadrus-mini-imager/quadrus-mini-imager_user-manual_1788315190.webp)
7-10
Quadrus MINI Imager User’s Manual
Bad Symbol Message
Bad Symbol Message
Note: Bad Symbol Message
is not supported when
Q-Mode
is enabled.
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For
<
:
<K715h,,3C>
For
>
:
<K715h,,3E>
For
,
:
<K715h,,2C>
See
ASCII Character Entry Modifier
on page 3-32 for a detailed explanation of how to
enter ASCII characters as hex values.
No Symbol Message
Note: No Symbol Message
is not supported when
Q-Mode
is enabled.
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For
<
:
<K716h,,3C>
For
>
:
<K716h,,3E>
For
,
:
<K716h,,2C>
See
ASCII Character Entry Modifier
on page 3-32 for a detailed explanation of how to
enter ASCII characters as hex values.
Usage:
Useful in determining if a symbol is present and if user defined requirements
for that symbol are met. Can tell the user if a qualified symbol is present but
not decodable.
Definition:
Sets the requirements that will qualify an object or a symbol before outputting a
decode or message. When enabled, sends a message to the host whenever
an object meets the qualifications setup but is not decoded.
Note:
When
Symbology Identifier
is enabled, the
Bad Symbol
message
is preceded by the identifier for the symbology being used.
Serial Cmd:
<
K715,
[unused],
message
>
Default:
BAD_SYMBOL
Options:
Up to 64 ASCII characters.
Usage:
Useful in determining if a symbol is present and if user defined requirements
for that symbol are met. Can tell the user if an object does not qualify as a
symbol.
Definition:
Sets the requirements that will qualify an object or a symbol before outputting a
decode or message. When enabled, sends a message to the host whenever
an object meets the qualifications setup but is not decoded.
Note:
When
Symbology Identifier
is enabled, the
No Symbol
message
is preceded by the identifier for the symbology being used.
Serial Cmd:
<
K716,
[unused],
message
>
Default:
NO_SYMBOL
Options:
Up to 64 ASCII characters.
Summary of Contents for Quadrus MINI Imager
Page 1: ...Quadrus MINI Imager User s Manual P N 84 006300 Rev...
Page 12: ...xii Quadrus MINI Imager User s Manual Statement of RoHS Compliance...
Page 98: ...4 20 Quadrus MINI Imager User s Manual Additional Notes about Calibration...
Page 128: ...5 30 Quadrus MINI Imager User s Manual Setting Up the Imager for EZ Trax...
Page 180: ...6 52 Quadrus MINI Imager User s Manual Background Color...
Page 238: ...7 58 Quadrus MINI Imager User s Manual Configuring EZ Trax Output...
Page 298: ...10 32 Quadrus MINI Imager User s Manual Skew Correction...
Page 318: ...11 20 Quadrus MINI Imager User s Manual Request All Configuration Database Settings...
Page 348: ...13 24 Quadrus MINI Imager User s Manual Other Operational Serial Commands...
Page 362: ...14 14 Quadrus MINI Imager User s Manual Ordered Output Filter...