![Microscan Quadrus MINI Imager User Manual Download Page 203](http://html1.mh-extra.com/html/microscan/quadrus-mini-imager/quadrus-mini-imager_user-manual_1788315203.webp)
Quadrus MINI Imager User’s Manual
7-23
I/O Parameters
Beeper
Note:
The beeper will also sound at any of the following times:
• When the imager is defaulted.
• When a send/save command is sent from
ESP
.
• At the conclusion of a calibration procedure.
• When a
<Z>
,
<Zp>
,
<Zrd>
, or
<K701,,1>
command is sent.
Usage:
An audible verification that either a good read or a No Read has
occurred.
Definition:
A beep is emitted after each good read or No Read.
Serial Cmd:
<
K702,beeper status
>
Default:
Good Read
Options:
0 = Disabled
1 = Good Read
2 = No Read