NL-200 Series Controller User’s Manual
B-1
B. Restrictions
The following timings and restrictions apply for firmware revision V002. The restrictions are applied
when settings are saved. Later firmware versions may have lesser limits.
B.1 Continuous Mode
The maximum output current is 4A.
B.2 Switched Mode
The maximum delay from a trigger input changing to the output current being turned on or
off is 10us.
The maximum output current is 0.5A.
B.3 Selected Mode
The maximum delay from a trigger input changing to the output current being turned on or
off is 5ms.
The maximum output current is 0.5A.
B.4 Pulse Mode
The maximum output current is 20A.
Pulses of 2A or more for pulse widths longer than 2ms might cause an error or have a lower
current towards the end of the pulse.
The minimum pulse delay is about 2us. When overdriving or using the retrigger delay, the minimum
delay is around 5us.
For pulse widths less than approximately 70us the output voltage and current cannot be measured.
Because of this, fault detection does not happen and the following restrictions apply:
•
For pulse currents greater than 0.5A, the duty cycle will be restricted to no more than 1%
•
For pulse currents less than or equal to 0.5A, the duty cycle will be restricted to no more
than 10%
Summary of Contents for NL-200
Page 1: ...NL 200 NL 220 NL 220F NL 820F LED Lighting Controller User s Manual P N 83 100022 Rev A...
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ...4 2 NL 200 Series Controller User s Manual Mounting...
Page 14: ......
Page 18: ......
Page 30: ......
Page 34: ......
Page 42: ......
Page 44: ......
Page 46: ......
Page 48: ......
Page 50: ......