11-6
NL-200 Series Controller User’s Manual
Command Configuration
(NL-220, NL-220F , NL-820F)
11.2.2 Command Summary
Command
Example
Effect
AW
AW
Save changes
GT
GT1
Enable Ethernet messages
GR
GR
Clear any error condition.
EY
EY65,66
Set webpage password to “AB”
VR
VR
Read the firmware version
VL
VL1,0,0.5
Set the rating of channel 1 to 0.5A
RS
RS2,65
Set channel 2 to 65% brightness continuous
RW
RW1,50
Set channel 1 to 50%, switch mode
RU
RU1,75,25
Set channel 1 to selected mode at 75% and 25%
RT
NL2,3,4,50
Set channel 2 to 3ms pulses, delayed by 4ms, at 50% brightness
RP
RP1,2
Output channel 1 is triggered using input 2
RE
RE1,3
Set channel 1 to ignore lighting errors and not prompt for the
current rating of a light when it is connected
TT
TT1,1ms
Set internal triggers every 1ms
KB
KB1,23
Disable the buttons on the front panel. Set the unlock code to 23.
TR
TR2
Trigger channel 2
NOTE: If the above commands are executed using the Web Page feature, they will not be executed
in the command entry area of the Web Page.