NL-200 Series Controller User’s Manual
11-5
Command Configuration
(NL-220, NL-220F, NL-820F)
Clear any Errors
GR
If Ethernet messages are not enabled, the last event or error number can be read by this
command. Any error displayed on the unit is cleared, so if there was a lighting error, the NL-
200 will resume auto-sensing on that channel.
The reply will be in he same form as the GT command above. If there are no outstanding
events or errors, then only the prompt “>” is returned.
Set/Clear the Webpage Password
EY
EY asc1, asc2, asc3, asc4, asc5, asc6
This command sets the password required to access the webpages. If EY is entered on its
own then the password is cleared. There are six optional parameters, which are decimal ASCII
values for a password from one to six letters. A value of 65 is ‘A’, 66 is ‘B’, etc to 90 is ‘Z’.
Disable Keypad
KBd,c
d = 0
Enable keypad
d = 1
Disable keypad, but allow unlock code
d = 2
Disable keypad, disable unlock code
c
Unlock code
In some applications it may be necessary to lock the keypad so that un-authorised operators
cannot change the settings.
A unlock code can be set. This can be used as a low-security way of allowing trusted users
to unlock the keypad. Ethernet commands and the web pages still work. The setting of this
command is restored after a power cycle.
Summary of Contents for NL-200
Page 1: ...NL 200 NL 220 NL 220F NL 820F LED Lighting Controller User s Manual P N 83 100022 Rev A...
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ...4 2 NL 200 Series Controller User s Manual Mounting...
Page 14: ......
Page 18: ......
Page 30: ......
Page 34: ......
Page 42: ......
Page 44: ......
Page 46: ......
Page 48: ......
Page 50: ......