11-2
NL-200 Series Controller User’s Manual
Command Configuration
(NL-220, NL-220F, NL-820F)
For example:
Parameter
Meaning
0.1
0.1 milliseconds
200us
200 microseconds
0.1s
0.1 seconds
100ma
100mA
2.45A
2.45A
2.3
2300mA or 2.3A
The command codes and their meaning are described below. The upper case commands are shown,
followed by lower case letters denoting the numeric argument.
Error number
Reason
Err 1
A parameter value is invalid
Err 2
Command not recognised
Err 3
Numeric value is wrong format
Err 4
Wrong number of parameters
Err 5
(This is only a warning) A timing parameter was
out of range and has been adjusted to a valid value.
Any changes made using Ethernet commands are not saved permanently until the AW command has
been issued.
11.2.1 General Commands
Report the version of firmware running in the NL220F
VR
This command returns the firmware version. For example:
NL-220F (HW001) V002
Set the rating of a light
This command sets the current or voltage rating for a light. If a current rating is being set,
then the voltage rating value should be 0.
VLo,v,c
Where:
o = output channel (1 or 2)
v = voltage rating (0 or 12 to 36)
c = current rating (0 or 10mA to 4A)
Summary of Contents for NL-200
Page 1: ...NL 200 NL 220 NL 220F NL 820F LED Lighting Controller User s Manual P N 83 100022 Rev A...
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ...4 2 NL 200 Series Controller User s Manual Mounting...
Page 14: ......
Page 18: ......
Page 30: ......
Page 34: ......
Page 42: ......
Page 44: ......
Page 46: ......
Page 48: ......
Page 50: ......