NL-200 Series Controller User’s Manual
11-3
Command Configuration
(NL-220, NL-220F, NL-820F)
Set continuous mode
The output is set to continuous mode at a percentage of full brightness.
RSc,
s
Where:
c = output channel (1 or 2)
s = setting in percent (s = 0 to 100)
Set switched mode
The output is set to switched mode at a percentage of full brightness.
RW
c,s
Where:
c = output channel (1 or 2)
s = setting in percent (s = 0 to 100)
Set selected mode
The output is set to selected mode with two brightness settings.
RU
c,s,t
Where:
c = output channel (1 or 2)
s = brightness 1 setting in percent (s = 0 to 100)
t = brightness 2 setting in percent (t = 0 to s)
Set pulse mode
The output can be set up to pulse on a trigger input. The delay from trigger to the start of the pulse,
the length of the pulse and the brightness are configurable.
An error is generated if the brightness setting requires a current greater than 20A or if the combination
of pulse width and setting is not allowed.
RT
c,p,d,s
RT
c,p,d,s,r
Where:
c = output channel (1 or 2)
p = pulse width in milliseconds (0.02 to 999)
d = delay from trigger to pulse in milliseconds (0.02 to 999)
s = setting in percent (s = 0 to 999)
r = retrigger delay. This parameter is optional
Set the Option Flags
REc,m
Where:
c = output channel (1 or 2)
m = flags:
bit 1 =
0 E flag set (error detection enabled)
1 E flag cleared (error detection disabled)
bit 2 =
0 P flag set (positive triggers)
1 P flag cleared (negative triggers)
Summary of Contents for NL-200
Page 1: ...NL 200 NL 220 NL 220F NL 820F LED Lighting Controller User s Manual P N 83 100022 Rev A...
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ...4 2 NL 200 Series Controller User s Manual Mounting...
Page 14: ......
Page 18: ......
Page 30: ......
Page 34: ......
Page 42: ......
Page 44: ......
Page 46: ......
Page 48: ......
Page 50: ......