d.
Suppression Occurs
Choose whether the output signal will get locked into a high or low (on the Fiber port these will be
displayed as illuminated or dark and for the HV MOSFET open or closed) state during suppression. The
'SUPPRESSION OCCURS' radio buttons are set to 'GO TO LOW STATE' by default.
7.
Save Settings
Click the 'SAVE' button to write the settings to the GridTime 3000.
A 'Saved!' notification will appear in the bottom right corner of the page indicating that the settings have
successfully been written to the GridTime 3000.
9.8.2
Provisioning G.703 Fixed Frequency Outputs
This section describes how to provision a GridTime 3000 Fixed Frequency/DCLS port to output a G.703 fixed
frequency signal.
Note:
Only the Fixed Frequency/DCLS BNC ports (Ports 3 and 4) can be used to output fixed frequency signals.
1.
Navigate to Port's Window
Navigate to the corresponding window for the port you want to configure by clicking on the correct port icon,
then clicking the settings bar corresponding to the port.
Provisioning
©