Page 33
optoCONTROL 1202
10.
Decommissioning, Disposal
Disconnect the power supply and output cable on the light source and receiver.
Incorrect disposal may cause harm to the environment.
Dispose of the device, its components and accessories, as well as the packaging materials in compli
-
ance with the applicable country-specific waste treatment and disposal regulations of the region of use.
11.
Optional Accessories
PS2020
Power supply (mounting on DIN-rail), output 24 VDC, input 240 VAC,
switchable for 110 VAC
CE1202-2
Connection cable transmitter/receiver, length 2 m
CE1202-5
Connection cable transmitter/receiver, length 5 m
SCD1202-2-RS232 Digital output cable for connection to an interface RS232, length 2 m
SCD1202-5-RS232 Digital output cable for connection to an interface RS232, length 5 m
SCD12xx-2-USB
Digital output cable incl. driver, length 2 m
SCA1202-2
Power supply and output cable, length 2 m
SCA1202-5
Power supply and output cable, length 5 m
ODC1202-L100
Mounting rail for ODC1202, 400 mm; distance light source/receiver max. 100 mm
ODC1202-L200
Mounting rail for ODC1202, 500 mm; distance light source/receiver max. 200 mm
ODC1202-L500
Mounting rail for ODC1202, 800 mm; distance light source/receiver max. 500 mm
EK1100/CSP2008
Bus terminal
EL3162/CSP2008
Bus terminal; 2-channel analog input terminal
CSP2008
Universal controller for displacement sensors
Further length are available on demand.