Page 7
optoCONTROL 1202
1.4
Proper Use
- The optoCONTROL 1202 is designed for applications in the industrial field.
- It is used
for edge acquisition, width or diameter measurement, position acquisition of components or machine
parts.
for measuring and testing problems in the process quality control
- The measuring system may only be operated within the limits specified in the technical data, see Chap.
- Use it in such a way that with malfunctions or total failure of the sensor, persons are not endangered and
machines are not damaged.
- Take additional precautions for safety and for damage prevention with safety-related applications.
1.5
Proper Environment
- Protection class
Electronics: IP 54
Optics: IP 67
-
Operating temperature:
-10 to +50 °C (+14 to +122 °F)
-
Storage temperature:
-20 to 85 °C ( -4 to 185 °F)
-
Humidity:
5 - 95 % (non-condensing)
-
Ambient pressure:
Atmospheric pressure