Page 16
optoCONTROL 1202
Pay attention that, when the transmitter and receiver are mounted freely, initially exact alignment of the
housing edges with respect to one another should be ensured. The housing edges must lie within one
plane.
Use a try square or other suitable aids for alignment of transmitter and receiver.
Pay attention on the alignment of target for avoiding measurement inaccuracies, see
Fig. 3 Measurement inaccuracy at tilted targets
Do not touch the optical windows. Contamination on the optical windows impairs correct functioning.
The optional available mounting rail for fixing of transmitter and receiver allows operating distances up to
2,000 mm.
Fix the mounting rail so that it is not bended respectively twisted.
i
Minimum distance between transmitter and receiver: 20 mm
Maximum distance between transmitter and receiver: 2,000 mm