Programming the Radio Parameters
85
•
ADT
Select the alternate display time-out, that is, the time after which a keypad sequence
is automatically aborted in case no action is taken. In this case, the display returns to
the previous screen.
The time-out interval can be selected in the range of 1 to 10 seconds.
•
ATTN
Enable/disable the use of the attenuator. The attenuator is used to reduce
interference when your radio is located near strong transmitters.
•
CW
Select the channel filter bandwidth used in the CW mode:
•
0.25
– 250 Hz
•
0.5
– 500 Hz
•
0.8
– 800 Hz
A lower value improves the reception but requires better frequency accuracy.
•
RCLV
Enable/disable the receive signal level display. If the receive signal indication is not
enabled, you can temporarily enable it using one of the function keys.
•
DIM
Enable/disable automatic dimming of the display.
Usually, the display operates continuously. However, you can program the display to
be normally off, and be automatically turned on when the transceiver detects any
type of activity (keypad, PTT, incoming call, etc.). The ADT option selects the time
before the display is again turned off when inactive.