Performance Specifications
RGC Range
5
µ
V to 1V (2 dB change in output level)
RGC Time Constants
Voice
Attack time 10 msec
Release time 1500 msec
Data
Attack time 10 msec
Release time 10 msec
Squelch
Constant SINAD (digital)
Clarifier Range
±
200 Hz in 10 Hz steps (see
Note 2
on page
vii)
Receiver Tuning Adjustments
None
Preselector Sections
Sub-octave (1.6 MHz to 30 MHz range)
Maximum Antenna Input
20 kV transient, 100V RMS for 2 minutes
Controls
Standard and optional: Volume, on/off, scroll, squelch, scan, USB/LSB, call,
monitor, priority, function and accessory/programming connector
Note 1
: Values noted as "Typical" are valid over 90% or more of the frequency range.
Note 2
: Optional for authorized dealers only.
Specifications subject to change without notice.
vii