Error-
code
Error message
Error description/ troubleshooting
#1003
on Tablet: "Error & Check
Station" + station number
on Terminal: „warning icon +
error code“
Error at Station: Squeegee didn’t start moving. Error-
code will be displayed at the station.
#1004
on Tablet: "Error & Check
Station" + station number
on Terminal: „warning icon +
error code“
Error at Station: Error screen lift. Check valve and
reed contact. Error-code will be displayed at the
station.
#1005
on Tablet: "Error & Check
Station" + station number
on Terminal: „warning icon +
error code“
Error at Station: Foil unit finish signal not received.
Error-code will be displayed at the station.
#2001
CAN Bus: Missing Station
Error at station parameter setting. Illegal gap in station
addressing.
#2002
CAN Bus: Missing Terminal
Terminal not found.
#2003
CAN Bus: Station behind
Terminal
Error at station parameter setting. Stations address
higher then terminal address.
#2005
Inverter Communication
Communication to main drive controller interrupted.
Check wiring.
#99xx
“Diverse Systemfehler” +
RE Fehl
please call MHM-Service
Please contact MHM service department for further
information.
#7000
Functionality not Supported
Wrong firmware on master PCB.
#7001
Incompatible Hardware found Update not possible because of wrong hardware
#7002
Functionality not Supported
Wrong software version on PCB
#7003
Different Software-Versions
Different software versions on PCBs
#4000
Error Position Sensors
Error position sensor signals. Check wiring.
#4001
Lift up Sensor missing
Lift up sensor signal is missing. Check adjusting,
wiring and function of the sensor.
#4002
Lift down Sensor missing
Lift down sensor signal is missing. Check adjusting,
wiring and function of the sensor.
#4003
Starting-Lockout
Starting lockout active. Index not possible. Check
input signal.
#4004
Off contact signal out of
range
Off contact position signal out of range. Check Master-
PCB parameters and wiring.
#4005
Off contact drive timeout
Off contact target not reached. Check mechanics,
wiring and Master-PCB setting.