Operating Instructions Synchroprint 5000
Operating instructions SP5000 V1-0.docx
Page 14 of 52
5.
Assembly
This section describes the external supply/connection ports of the Synchroprint and the points to be
observed during assembly.
5.1.
General Assembly Instructions
The customer should have a minimum of two persons available to assist the technician with the
installation and assembly of the machine.
5.2.
Positioning of the Synchroprint
The machine must be mounted on a bed with sufficient load-bearing capacity. In case of doubt this
capacity is to be examined by a structural engineer.
In order to guarantee perfect installation and smooth operation of the Synchroprint, the machine
must be installed at a sufficient distance from adjacent elements of the building (walls, columns,
etc.) and/or other machines. The distance required in each case depends on the screen size, and must
be chosen so as to allow the operator to replace the screens without any problems. The dimensions
of the respective machine are indicated in Chapter “3 Data”.
5.3.
Ambient Conditions
For the electrical equipment on the Synchroprint, ambient conditions according to standard IEC
60204 “Electrical Equipment of Industrial Machines” should be observed.
The following points should be observed in order to achieve efficient running and an optimum level
of production with the Synchroprint:
1.
The premises, where the Synchroprint is to be operated, must be kept clean, dry and well-
aired.
2.
The ambient temperature must not fall below +5° C or 45° C.
3.
Relative air humidity must not exceed 80 %.
4.
The mains supply must not exceed or fall below a tolerance of +/- 5 % of the required
voltage for the Synchroprint. If this voltage stability cannot be guaranteed, the customer
must install a constant-voltage regulator to protect the Synchroprint against such
fluctuations.
5.
The compressed air must be clean, filtered and dry (class 1:4:1 according ISO8573-1:2010).
6.
Compressed air supply must be sufficient in terms of pressure, volume and consistency.
7.
Electricity supply should be sufficient with adequate fuse protection.
8.
Maximum installation altitude is 2000m above sea level.
The Synchroprint must only be installed / assembled by a service technician of
the machine manufacturer or by an authorized service technician from an
official MHM dealer/agent. Any assembly/installation by any third party not
listed above will result in immediate cancellation of the warranty.