TROUBLESHOOTING CHAPTER
11
4
ENGINE CONTROL
WHILE ENGINE RUNNING
All modules not up
Engine stopping
Module missing alarm 37,
38 or 39 Check function of
the emergency relay
Radio
selected
Engine stopping
Alarm 27
Check ECM XM1 input 15
Radio
remote stop
Drive box
connected
Engine stopping
Alarm 26
Check DCM XM3 input
22
Drive box
remote stop
Hydr oil temp
high
Yes
Yes
Yes
Process running
Yes
Disable process
Alarm 1
Hydr oil main
valve closed
Yes
Engine stopping
Alarm 16
Check : ECM
XM2 input 18
Check suction
valve position
Hydr oil level
down
Engine stopping Alarm 10
Check: ECM XM2 input 17
Check actual oil level at hydraulic
Yes
Yes
Yes
Yes
Engine running
Emergency stop
Engine stopping
Alarm 28 ES from control panel
Check HUB XH4 input 11
!
repair wiring or contact
Alarm 29 ES Service platform
Check HUB XH4 input 12
!
repair wiring or contact
Alarm 30 ES from engine module
Check HUB XH4 input 13
!
repair wiring or contact
Alarm 31 ES from hydraulic center
Check HUB XH4 input 14
!
repair wiring or contact
Yes
Engine stopping
Alarm 17
Check: ECM XM3 input 13
Check cooler and hydarulic
oil temperature
No