TROUBLESHOOTING CHAPTER
11
3
Engine start motor
running
Releasing key switch
from start position
Main valve
Engine stopping Alarm 16
Check : ECM XM2 input 18
Check suction valve position
Hydraulic oil level
Closed
Engine stopping Alarm 10
Check: ECM XM2 input 17
Check actual oil level at hydraulic tank
Down
Engine start continue
J1939 bus fault
Engine stopping Alarm 11
Check fuse 2F07
Check fuse 2F06
Check ECM XM2 output 6 & relay 2K03
Yes
OK
OK
No
Yes
No
Engine start motor is running but engine
does not start:
Check fuel amount , Fill and bleed fuel
system
Manifold preheater function:
Check fuse for preheater – side by the
engine.
Check active diagnostic code from the
DCU page 5.3.2
ENGINE RUNNING
Yes
No
Check ECM XM2 output 5
Check fuse 2F02