TROUBLESHOOTING CHAPTER
11
14
FEEDER START UP
Engine control
Feeder stop ?
Feeder start from
radio ?
Feeder start from
service platform ?
Feeder start from
process ?
Feeder start for-
ced from dislay ?
Feeder power &
control ON
Feeder running
Feeder not
able to start
Fault
Yes
Yes ( radio contrtol on & active )
Yes
Yes
Yes
Feeder ready for
material feed
Yes
Check: feeder power HCM XM2
output 5 ( "1" = ok "0" not ok )
Measure voltage at terminal 3X3 – 81
Check: feeder control measure voltage
at terminal 3X3 – 43 ( 17 – 19 V ok if
Udc 27,5 V). Check manually valve
operation. Replace valve control head if
nesessary.