Page 131
Error message
Meaning of the error message Measures
Main
index
Sub
index
34
0
No synchronisation via the field
bus
Failure of synchronization messages from
master?
1
Field bus synchronisation error Failure of synchronization messages from
master?
Insufficient synchronisation interval?
35
0
Overspeed protection of the
linear motor
The encoder signals are disturbed. Check the
installation for compliance with EMC
recommendations.
5
Error during the determination
of the commutation position
The selected method is not suitable for the
motor. Please contact the Technical Support.
36
0
Parameter limited
Check the user parameter set.
1
Parameter not accepted
37
0
Sercos:
received data disturbed
Check the sercos wiring (clean the optical
waveguide, for example).
Check the luminous power settings.
Check the baud rate.
1
Sercos:
optical waveguide loop
interrupted
Check the sercos wiring (optical waveguide) for
breaks.
Check the connections.
2
Sercos:
double MST failure
Check the sercos wiring (optical waveguide).
Check the control system (are all of the MSTs
being transmitted?)
3
Sercos:
illegal phase specification in the
MST info
Check the program in the Sercos master.
4
Sercos:
double MDT failure
Check the sercos wiring (optical waveguide).
Check the control system (are all of the MDTs
being transmitted?)
5
Sercos:
unknown operation mode
selected
Check the settings for the operating modes in
the IDN S-0-0032 to S-0-0035.
6
Sercos:
T3 invalid
Increase the baud rate.
Shift the point of time T3 manually.
Product Manual „Servo drives ARS 2100 SE“