Error message
Meaning of the error message Measures
Main
index
Sub
index
58
0
FSM: Plausibility check of
parameters
Cause: The plausibility check in the safety
module produced errors, e.g. an invalid
angle encoder configuration; the error
is triggered when a validation code is
requested by the SafetyTool and when
parameters are backed up in the safety
module.
Action:
Note instructions for SafetyTool for
complete validation; check
parameterisation.
1
General error, parameterisation Cause: Parameter session active for > 8 hrs.
The safety module has thus terminated
the parameterisation session.
The error message is saved in the
permanent event memory.
Action:
Terminate parameterisation session
within 8 hrs. If necessary, start a new
parameterisation session and continue.
4
Buffer, internal communication
Cause:
Communication connection faulty.
Timeout / data error / incorrect
sequence (packet counter) in data
transmission between the basic
device and safety module.
Too much data traffic, new requests
are being sent to safety module
before old ones have been
responded to.
Action:
Check communication interfaces,
wiring, screening, etc.
Check whether other devices have
read access to the servo drive and
safety module during a
parameterisation session - this may
overload the communication
connection.
Check whether the firmware
versions of the safety module and
basic device and the versions of the
Metronix ServoCommander® and
SafetyTool are compatible.
Product Manual „Servo drives ARS 2100 SE“