7 Mechanical installation
7.1 Important notes
Only use the servo drive ARS 2100 SE as a built-in device for switch cabinets
Mounting position vertical with supply lines [X9] on top
Mount to control cabinet plate using a fastening strap
Installation free spaces:
Keep a minimum distance of 100 mm to other components each above and underneath the device
to ensure sufficient venting.
For optimal wiring of the motor cable and angle encoder cable on the bottom of the device an
installation free space of 150mm is recommended!
Mounting distance:
The servo drive ARS 2100 SE may be installed adjacently in one switch cabinet without a gap,
proper usage and installation on a heat-dissipating rear panel provided. Please note that
excessive heat may cause premature aging and/or damaging of the device. In case the servo
drives ARS 2100 SE are subject to high thermal stress, a mounting distance of 59 mm is
recommended (see
).
The device views and connections of the following illustrations apply to the servo drives
ARS 2102 SE, ARS 2105 SE and ARS 2108 SE.