Rear Side of the Housing
Setup and Functioning
26
/
88
05.02.2019
8LE-D23_BA_E.docm
4.3.2 Establishing Signal Connections
Pos.:
Description
1
LED +9 V I/O
2
CAN-Bus
OUT
(Figure 13, Page 27)
3
LED CAN-bus TX active
4
LED V I/O external
5
CAN-Bus
IN
(Figure 12, Page 27)
6
LED CAN-bus RX active
7
CAN-bus address (MSB)
8
CAN-bus address (LSB)
Figure 11: CAN-bus on the rear side of the housing
Connect M=LIGHT LED with the control PC.
Connect the RJ45 input
IN
of the first M=LIGHT LED with the M=LIGHT LED BUS Splitter.
Connect the RJ45 output
OUT
of the first M=LIGHT LED with the input
IN
of the second
M=LIGHT LED.
Connect additional M=LIGHT LED accordingly.
Specify an individual CAN-bus address for each M=LIGHT LED in the same CAN-bus line.
Restart M=LIGHT LED.
Now, the signal connections have been completely established.
The CAN-bus and the Sync bus are automatically terminated by the internal terminating resistor of
the M=LIGHT LED last connected.
For the connection of the M=LIGHT LEDs, use a patch cable according to CAT5
EIA/TIA-568 or higher.