Operate M=LIGHT LED in manual mode
Handling
84
/
88
05.02.2019
8LE-D23_BA_E.docm
8.2
Operate M=LIGHT LED in manual mode
Pos.: Description
1
EMC filter
2
Supply connection for
hot devices power
supply cord
3
Nameplate
4
RJ45 Ethernet
Connection
CAN-bus Out
5
RJ45 Ethernet
Connection
CAN-bus In
6
CAN-bus address
(MSB)
7
CAN-bus address
(LSB)
8
On / Off-switch,
manual operating
mode.
Figure 66: Connections and control elements on the rear side
In the case the M=LIGHT LED has NOT yet been parameterized via CAN-bus, manual mode is
activated automatically when applying the power supply.
8.2.1 Set M=LIGHT LED WITHOUT RJ45 Ethernet connection
Disconnect M=LIGHT LED from RJ45 Ethernet connection (Figure 66, Page 84, Pos. 4).
Supply M=LIGHT LED with operating voltage.
Press the
ON
button on the rear of the housing (Figure 66, Pos. 8).
M=LIGHT LED is in manual mode.
The intensity can be set with the CAN-Bus address switches on the rear of the M=LIGHT LED
(Figure 66, Pos. 6 and 7).