4-12
Revised 08.2021
Operator’s Manual: 405 SLD Seed Express
™
Bulk Seed Tender
®
®
Fig 79 - Control panel
4.3.11 Control Panel Error Codes:
Error Code Outputs:
The receiver module can identify problems with
the system in the form of an error code. Check
red indicator light (a) on the receiver to diagnose
system problems.
Each of the outputs from the receiver module is
designed with built-in short circuit and overload
protection. The outputs can also detect a no-
-load or broken wire condition.
These error conditions are indicated by the red
LED indicator on the receiver module or the
HISTOGRAM page on the optional Palm Pilot™.
Refer to the Error Code Chart for explanation
of the error codes. Green LED indicator light
(b) will blink on the receiver during normal
communication.
The ON/OFF outputs will indicate an error under
no load or broken wire status if NOT activated,
and will detect a short if activated.
Table 1 - Control Panel Display Error Codes
ERROR CODE
CAUSE
SOLUTION
1
RF Communication
Transmitter is OFF.
Transmitter went into sleep mode.
Interference in RF communication link.
2
Wrong ID
Transmitter and receiver are not synchronized.
3
Scale Bar Fault
RS-232 communication cable between scale unit and receiver is
damaged, disconnected, or the scale unit is OFF.
4
Low Battery
System voltage is below 10.5 Volts.
5
Conveyor Speed Fault
Check for short or open circuit.
6
Engine Start Fault
Check for short or open circuit.
7
Engine Stop Fault
Check for short or open circuit.
8
Conveyor Lift Fault
Check for short or open circuit.
9
Conveyor Lower Fault
Check for short or open circuit.
10
Conveyor Left Fault
Check for short or open circuit.
11
Conveyor Right Fault
Check for short or open circuit.
12
Slide Gate 1 Open Fault
Check for short or open circuit.
13
Slide Gate 1 Close Fault
Check for short or open circuit.
14
Slide Gate 2 Open Fault
Check for short or open circuit.
15
Slide Gate 2 Close Fault
Check for short or open circuit.
Note:
Error codes are invalid during manual operation.
b