INSTRUMENTATION
SERVICE MANUAL NUMBER 23
90-861326--1 MARCH 1999
Page 4D-5
Gauges
Oil, Fuel and Temperature
IMPORTANT: If testing proves gauge to be defective, it must be replaced as there is
no repair available.
TESTING
1. Turn ignition switch to OFF.
2. Remove wire from terminal S (SEND).
72965
a
Typical
a -
Terminal S (SEND)
3. Turn ignition switch to RUN. Gauge being tested must be at position A.
72747
Position A (Typical)
4. Turn ignition switch to OFF.
5. Connect jumper wire from terminal G (GND) to terminal S (SEND).
72748