TROUBLE CODE DIAGNOSTICS - 7.4L MPI
SERVICE MANUAL NUMBER 23
90-861326--1 MARCH 1999
Page 5G-57
Code 34 (3 of 3): Manifold Absolute Pressure (MAP) Sensor Circuit (Scan) -
Low Signal Voltage
STEP
ACTION
VALUE
YES
NO
PROCEED TO
6
Repair low or unsteady vacuum problem.
Is
action complete?
–
–
7
Trouble code is intermittent. Locate and repair
intermittent faulty connections. Refer to “Diag-
nostic Aids”.
–
–
8
Locate and repair open or short to ground in
CKT 416E. If a problem is found, repair as
necessary.
Was a problem found?
–
Verify
Step 11
9
Locate and repair open or short to ground in
CKT 432. If a problem is found, repair as nec-
essary.
Was a problem found?
–
y
Repair
Step 11
10
Check for plugged or leaking sensor vacuum
fitting. If OK, replace faulty MAP sensor.
Is
action complete?
–
–
11
Repair faulty ECM connections or replace
faulty ECM.
Is action complete?
–
–
Downloaded from
https://needmanual.com/
Index