STARTING SYSTEM
SERVICE MANUAL NUMBER 23
Page 4A-22
90-861326--1 MARCH 1999
4. Remove armature and field frame from drive housing.
5. Pull armature out of field frame.
NOTE: Permanent magnets inside field frame will be holding armature in place.
74086
b
a
a -
Armature
b -
Field Frame
6. Remove shield and washer.
74038
a
b
a -
Shield
b -
Washer
7. Remove the three screws retaining the solenoid. Remove solenoid from drive housing.
74036
b
a
c
a -
Drive Housing
b -
Solenoid
c -
Screws (2)