INSTRUMENTATION
SERVICE MANUAL NUMBER 23
Page 4D-12
90-861326--1 MARCH 1999
Water Temperature
Ohms Reading
140
°
F (60
°
C)
121-147
194
°
F (90
°
C)
47-55
212
°
F (100
°
C)
36-41
3. Replace sender if ohmmeter readings are other than as shown for each temperature.
INSTALLATION
1. Apply Loctite Pipe Sealant with Teflon to threads of temperature sender.
2. Install sender in thermostat housing and tighten securely.
a
b
a -
Water Temperature Sender
b -
Thermostat Housing
3. Connect tan wire and coat with Liquid Neoprene.
4. Refill closed cooling system with approved coolant as outlined in SECTION 6B.
Fuel Tank Sender
FLANGE TYPE
Testing
1. Disconnect wire from terminal on sending unit and ground wire from sending unit
mounting screw.
2. Remove sending unit from fuel tank.
3. Connect ohmmeter between sending unit terminal and sending unit housing.