Section 2 - Getting to Know Your Power Package
90-8M0050539
eng
MAY 2011
Page 41
The power trim system is protected from overload by both a 110 amp fuse and a 20 amp spade fuse on the power trim pump. The
trim pump may also have an in‑line circuit protection device in the power trim positive lead near the battery switch or battery
connection.
a -
20 amp spade fuse
b -
110 amp fuse
A power harness, connected to the engine starting battery, minimizes voltage drop to the electrical system. This harness is
protected by a 5 amp fuse. This connection is located at the rear of the engine, near the 14‑pin connector.
33179
Power harness connection
The Quicksilver Three‑Button Power Trim Control Panel is protected by a 20 amp in‑line fuse.
mc70527-1
a
b
9208