Section 6 - Storage
Page 134
90-8M0050539
eng
MAY 2011
2. Remove the blue drain plug from the distribution housing (lower front, port side).
a -
Blue drain plug
3. To properly vent the cooling system, remove the blue drain plug from the side of the thermostat housing within 30 seconds.
a -
Blue drain plug location
4. Remove the two blue drain plugs from the seawater pickup pump (front, starboard side).
a -
Blue drain plugs
5. Verify that water is draining from each opening.
6. Allow the system to drain for a minimum of five minutes. We recommend leaving the drain system open while transporting
the boat or performing other maintenance to ensure that all water is drained.
7. Crank the engine over slightly with starter motor to purge any water trapped in the seawater pickup pump. Do not allow the
engine to start.
8. Before launching the boat or starting the engine, close the drain system by installing the four blue drain plugs.
9. Open the seacock, if equipped, or unplug and reconnect the water inlet hose prior to operating the engine.
Boat out of the Water
NOTE: Use this procedure if your engine is not equipped with an air‑actuated single‑point drain system or if the single‑point drain
system fails.
1. Place the boat on a level surface to ensure complete draining of the system.
6138
a
a
6139
a
6140
Summary of Contents for MerCruiser Axius SeaCore 350 MAG
Page 28: ...Section 1 Warranty Notes Page 20 90 8M0050539 eng MAY 2011...
Page 56: ...Section 2 Getting to Know Your Power Package Notes Page 48 90 8M0050539 eng MAY 2011...
Page 70: ...Section 3 On the Water Notes Page 62 90 8M0050539 eng MAY 2011...
Page 162: ...Section 7 Troubleshooting Notes Page 154 90 8M0050539 eng MAY 2011...