Section 3 - On the Water
Page 34
90-879172181
eng
FEBRUARY 2011
IMPORTANT: To avoid excessive exhaust aeration of the seawater, do not operate the engines over 1500 RPM when the
vessel is at rest.
12. If you must operate the engines above 1500 RPM, put the vessel underway with a light throttle load until the engines reach
normal operating temperature.
Stopping the Engine Using the VIP SmartStart Switch
You may desire to stop an engine from the engine room or under certain circumstances the engine control system may not be
able to automatically stop an engine. The engines can be stopped using the "SMARTSTART" (stop/start) switch on the VIP for
each engine.
1. Move the ERC handles to the neutral position.
2. Locate the VIP for each engine in the engine room.
3. Inside the VIP for triple or quad installations, turn the engine selector switch to the desired engine or engines.
4. When the engines are running, press and release the start/stop switch or the green "SMARTSTART" (stop/start) switch for
each engine you want to stop.
Typical SmartCraft 2.2 VIP
a -
Red "E‑STOP" switch—for emergency use only
b -
Green "SMARTSTART" (start/stop) switch
Typical SmartCraft 3.0 single VIP for triples
a -
Engine selector switch
b -
Start/stop switch
c -
Panel
33930
a
b
ENGINE
PORT
START/STOP
STBD
ENGINE
CENTER
ENGINE
a
b
c
43957
Summary of Contents for 92-858058K01
Page 4: ......
Page 8: ...Page iv 90 879172181 eng FEBRUARY 2011...
Page 78: ...Section 3 On the Water Notes Page 70 90 879172181 eng FEBRUARY 2011...
Page 128: ...Section 5 Maintenance Notes Page 120 90 879172181 eng FEBRUARY 2011...
Page 140: ...Section 7 Troubleshooting Notes Page 132 90 879172181 eng FEBRUARY 2011...
Page 146: ...Section 8 Customer Assistance Information Notes Page 138 90 879172181 eng FEBRUARY 2011...