purge zone
11
Filter maintenance
Micron gear series melter equipment is equipped with a 50 mesh pump filter.
The filter prevents impurities and burnt adhesive remains from being pushed
out from the tank by the pump.
Warning:
It is a good idea to also use a grill in the tank. This grill performs a
first-step filtration, preventing great impurities.
The adhesive flows from the inside to the outside of the filter, with impurities
being trapped inside it.
The drain valve is included in the filter cap.
When the filter is removed from its housing, all the impurities remain trapped
inside, and the inside of the distributor stays perfectly clean. The filter may be
cleaned or replaced directly with a new one.
No rule exists for determining when to change the filter. Several factors
influence this decision:
• The type and purity of the adhesives used.
• The adhesive work temperatures.
• Adhesive consumption in relation to the time it spends in the tank.
• Changes in the type of adhesive used.
In any case, we recommend checking and cleaning the filter at least every
1000 hours of operation (melter equipment turned on).
Warning:
Always use protective gloves and goggles. Risk of burns.
To change the filter, it should be borne in mind that the filter and purge valve
are the same assembly:
1. Depressurise the system and open the casing shown.
2. Using a flat blade screwdriver, open the drain valve contained in the
filter head anticlockwise (1) and wait until any remaining adhesive has
fallen down the ramp.
3. To remove the whole filter, unscrew the assembly’s hexagonal plug
using a 22 mm socket driver and remove it.
4. Depending on the amount of dirt inside the cartridge, clean it or throw
it away, following the applicable waste regulations.
5. Replace the joints if they are damaged.
6. Screw the assembly up again, clockwise.
Summary of Contents for Micron PUR LC
Page 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Page 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Page 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Page 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...