MELER GLUING SOLUTIONS
2-6
INTRODUCTION
(1)
In case of simple pump up to 6 outputs but in case of double pump up to 4.
(2)
In the case of two single pumps or two double pumps, place a 2 before
the pump type (SX or DX). In the case of one single pump and a double pump,
place the single pump (SX) first followed by the double pump (DX). The maxi-
mum number of pumps is two per equipment.
Micron PUR series range
PUR LC
PUR series
Tank capacity _
5: 5kg • 10: 10kg • 20: 20 kg • 35: 35 kg
2 M01 200 BE S4 PC
Electrical outputs _
2 • 4 • 6
Sensory type _
M01: Pt100 • N01: Ni120 • R01: NTC-R
Maximum temperature _
200: 200°C • 230: 230°C
Gear pump size __
S1: 1cc/rev • S2,5: 2,5cc/rev • S4: 4cc/rev • S8: 8cc/rev
D0,93: 2x0,93cc/rev • D1,86: 2x1,86cc/rev • D3,71: 2x3,71cc/rev • D4,8: 2x4,8cc/rev
* repeat for each pump installed separated by ‘/’ ; if there are two equal, once a ‘2’ before
Bypass valve pressure control _
MC: Mechanic control • PC: Pneumatic control • VP:
Proportional valve • P1: double pressure (reg network) • P2: double pressure
(external regulation)
/
A
CL LD2 B1 SW MB
S
UL
Air-dryer system _
(in blank): without dryer system •
A: with dryer system
Level detector _
(in blank): No level detector • LD1: buoy detector
installed • LD2: with capacitive detector installed • LD3: with high & low
capacitive detectors installed
Light tower _
(in blank): No light tower • B1: Low level•/ B2: Low
level & temperature ok • B3: temperature ok
Pump on/off connector _
(in blank): No switch connector •
SW: with switch connector
Communications _
(in blank): No communication •
MB: ModBus • PB: ProfiBus • PN: ProfiNet •
EN: Ethernet-IP • W: Wifi
Starbi integration
(in blank): Not integrated •
S: Starbi integrated (2 channels)
Control fusor _
(in blank): Internal •
E: Prepared for external melter control
-
E
Automatic feeder _
(in blank): No feeder system • CL: external feeding from
premelter
Certifications _
(in blank): CE
Summary of Contents for Micron PUR LC
Page 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Page 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Page 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Page 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...