![Meler Micron PUR LC Instruction Manual Download Page 46](http://html1.mh-extra.com/html/meler/micron-pur-lc/micron-pur-lc_instruction-manual_1767109046.webp)
MELER GLUING SOLUTIONS
4-12
MELTER OPERATION
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
150
5
+
-
General Variation
General Set-Point
General Standby
General OFF
Temperature
State
Area
Real
Set Point
T: Tank
152
150
D: Distributor
150
150
1.1: Hose 1
49
OFF
1.2: Applicator 1
170
155
2.1: Hose 2
130
145
2.2: Applicator 2
100
100
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
Group OFF
OFF Group: 1
Temperature
State
Area
Standby
OFF
T: Tank
D: Distributor
1.1: Hose 1
1.2: Applicator 1
2.1: Hose 2
2.2: Applicator 2
General Standby
General OFF
1
2
3
1
2
3
3
4
5
Programming of temperatures
1. Enter a temperature in ‘General set point’ to simultaneously program all
the zones with that temperature value.
2. To make quick adjustments, enter a variation value in ‘General variation’
and add (+) or subtract (-) it from the ‘General set point’ value. The value
is simultaneously added or subtracted in all zones.
3. To program each zone individually, click on the ‘Set point’ value and enter
the new desired temperature value.
Programming of statuses
1. Press ‘General Standby’ to activate (green) or deactivate (grey) the Stan-
dby mode in all zones.
With the ‘General Standby’ mode activated (Equipment in Standby) it is
not possible to activate each Zone individually.
2. Press ‘General Off’ to activate (green) or deactivate (grey) the Inhibition in
all zones.
With the ‘General Off’ mode activated (Equipment OFF) it is not possible
to activate each Zone individually.
3. To inhibit a group of zones, select the group and activate the inhibition
(green). To define the different groups, see the ‘Inhibitions’ point.
4. Press ‘Standby’ in each zone to individually activate (green) or deactivate
(white) the Standby mode.
5. Press ‘OFF’ in each zone to individually activate (green) or deactivate
(white) the inhibition..
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
C1 C2 C3 C4 C5 C6
Calendar
Hour
ON
Standby
OFF
07:00
11:00
13:15
15:00
00.00
00.00
Enable all the calendars
M
T
W
T
F
S
S
Menú Calendars
This menu allows you to program a calendar with the unit’s status changes.
Once it is activated, the unit changes from one status to another automatically.
When the unit is switched on, it does so in the mode that has been program-
med in the calendar, if the calendar is activated.
You can create up to six calendars (C1, C2, etc.) and up to six status changes
per day, indicating whether the unit will be in ON, Standby or Inhibition (Off).
From the ‘Select all calendars’ option, you can simultaneously activate or
deactivate all the calendars you have created.
You can add different days of the week to each calendar. Keep in mind that a
single day cannot be programmed in two active calendars. Therefore, if a day
of the week is programmed in an active calendar, it can only appear in other
calendars if they are disabled.
Summary of Contents for Micron PUR LC
Page 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Page 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Page 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Page 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...