![Meler Micron PUR LC Instruction Manual Download Page 66](http://html1.mh-extra.com/html/meler/micron-pur-lc/micron-pur-lc_instruction-manual_1767109066.webp)
MELER GLUING SOLUTIONS
4-32
MELTER OPERATION
‘Automatic pumping block’ disabled
When this function is disabled, whenever an event forces the unit to change to
ERROR mode, STANDBY mode or OFF mode, it will automatically return to RE-
ADY mode once the conditions are met again. You do not have to press STOP.
The red LED will remain off.
Example:
The unit is in RUNNING mode. At this moment, the tempe-
rature is not OK, and after the programmed time has passed, the unit
changes to ERROR mode. When the temperature is OK again, the unit
automatically changes to READY mode.
Warning:
It is always possible to put the unit in STOPPED mode by pressing
STOP. The red LED will light up. In this case, even if permitted by the condi-
tions, it will not be possible to return to READY mode until you press STOP
again and the LED turns off.
Warning:
Whenever the ‘Automatic pumping block’ function is disabled, it is
recommended for the ‘ON/OFF’ or ‘OFF Pumping’ signal of the unit to be con-
nected to the main machine, so that this signal can be used to enable the unit
again in a controlled manner.
PISTÓN
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
10 min
85 °C
60 s
Modbus
B: 57600
Node: 10
2.2 Extra Settings
Inside device temperature alarm
Off after reset
Screen saver
Sound on alarm
Pumping autolock
Press to
activate
pumping
STOPPED
MODE
READY
MODE
Press to
deactivate
pumping
Summary of Contents for Micron PUR LC
Page 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Page 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Page 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Page 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...